{"id":6593419575392,"title":"Kitchen Counter Pop Up Receptacle, 20A GFCI, Plastic Back Box, Dark Bronze","handle":"lew_pufp-ct-db-pb","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg style=\"margin-top: 10px; margin-right: 6px; margin-bottom: 6px; float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT-SS-AC-PBGIF_480x480.gif?v=1702520985\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan style=\"color: #59115a;\"\u003e\u003cstrong\u003eLew Electric PUFP-CT-DB-PB Pop Up Countertop GFCI Outlet in Dark Bronze\u003c\/strong\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003eThe pop up power outlet box is designed to be hidden in kitchen countertops, or any worktop surface that needs protection from liquids while meeting UL 498 code. When in the closed position, the outlet sits recessed in the counter, creating a sleek and attractive appearance. When access to power is needed, simply press the oval button and the outlet flips up for use. The durable metal top is a dark bronze color that is perfect for matching dark countertops or oil rubbed bronze fixtures. \u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan style=\"color: #59115a;\"\u003e\u003cstrong\u003eMeets NEC Electrical Code 2023 406.5E for Installation in Countertops\u003c\/strong\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe pop up meets 2017, 2020, and 2023 NEC 406.5E for kitchen countertop installations in the USA and Canada. The single duplex GFCI outlet has tamper-proof plugs and is UL 498 listed. The pop up has passed the UL 498 half gallon spill test, as well as endurance, mechanical load, dielectric voltage, and temperature tests. There is also a gasket under the bezel to keep liquids from entering the sides between the countertop and the base of the pop up.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #59115a;\"\u003e\u003cem\u003e\u003cstrong\u003eEasy to Thread on Lock Nut Installation with a Shallow Depth\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe pop up only needs 1.97” of space under a 3cm countertop, and requires a 4 1\/8” x 4 1\/8” hole to be cut for installation. A plastic back box features a lock nut that makes it extremely easy to install, simply thread the lock nut on the box to secure to the underside of the counter. The outlet does not have a power cord; simply hardwire power into the outlet by running it through the knockouts in the rear of the back box.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #59115a;\"\u003e\u003cem\u003e\u003cstrong\u003eTamper Proof GFCI 20A Outlet for Safety\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe outlet is 20 Amp rated allowing the most power hungry small appliances to be plugged in. The outlet has integrated GFCI protection providing safety right at the source, if the outlet recognizes an unsafe interruption in the current, it will automatically shut off power to the outlet. The plugs are tamper resistant (TR) meeting code, and offer the peace of mind knowing that children can't put small objects into the sockets and electrocute themselves. The 20A outlet is backwards compatible with 15A plugs, meaning that both 15A plugs and 20A plugs, can be plugged into the outlet. The outlet meets the ANSI\/UL 943 standard for safety for ground fault circuit interrupters. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e***NEC 2023 Code states that outlets can no longer be placed on the sides of islands anymore, use an approved pop up outlet in your countertop that meets UL 498 code***\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #59115a;\"\u003e\u003cem\u003e\u003cstrong\u003eIn-Counter Outlet Where it is Needed Most\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA centrally located inset countertop tilt up outlet adds convenience to provide power and charging where needed most. Eliminate the need to plug into the side of an island, and unsafely drape cords over the edge of the counter. Never again run cords over the counter hoping it reaches the middle of your island. If you are wanting to meet 2023 code, then you can place the outlet in the top of the countertop.  Pop up outlets provide a functional, safe, and beautiful look in your countertop.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan style=\"color: #59115a;\"\u003e\u003cstrong\u003ePlug in Power for Numerous Applications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Lew Electric PUFP-CT-DB-PB meets electrical code for kitchen countertop installations, but can also be used in any other potentially wet locations that require recessed power such as pantries, closets, garage work benches, bars, and varied uses at airports, hotels and restaurants. Use the pop up to power small appliances such as coffee makers, blenders, toaster ovens, warming trays, and other items. It can also be used for charging mobile devices such as tablets and phones with an appropriate adapter. The pop up can be installed in granite, quartz, marble, wood, laminate, concrete, or any surface up to 1.9\" where the required 4 1\/8” x 4 1\/8” hole can be cut.\u003c\/p\u003e\n\u003cp\u003eWatch a customer demonstration video \u003ca href=\"https:\/\/www.youtube.com\/shorts\/uBwhdfs27Cw\" target=\"_blank\"\u003eCLICK HERE.\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan color=\"#59115a\" style=\"color: #59115a;\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-lg-5 col-lg-5-offset-2\"\u003e\n\u003cp\u003eColor:  Dark bronze metal top\u003cbr\u003e Outlet:  20 Amp GFCI\u003cbr\u003e Tamper resistant (TR) plugs\u003cbr\u003eWeather resistant (WR) outlet\u003cbr\u003e Meets 2017 to 2023 NEC code 406.5E\u003cbr\u003e ETL listed for USA installations, # 4004534\u003cbr\u003ecETL listed for Canada installation, # 4004534\u003cbr\u003eCSA approved for Canada, #C22.2\u003cbr\u003eConforms to UL 498 and 943\u003cbr\u003eUL listed receptacle, # E60120\u003cbr\u003ePassed half-gallon spill test\u003cbr\u003ePassed endurance, mechanical, dielectric, temperature tests\u003cbr\u003e Gasket under bezel to keep water out\u003cbr\u003e Bezel size:  4 7\/8” x 4 11\/16”\u003cbr\u003e Cutout size:  4 1\/8” x 4 1\/8”\u003cbr\u003e Depth under 3cm counter:  1.97”\u003cbr\u003e Back box dimensions:  4.1062” x 4”\u003cbr\u003e Works in counter thickness up to 1.9”\u003cbr\u003e Hardwired power, no corded plug\u003cbr\u003e Includes back box with threaded lock nut, screws\u003cbr\u003e Installation should be done by a licensed electrician\u003cbr\u003e Consult with electrician\/inspector before ordering \u003cbr\u003eDesigned for indoor installations only\u003cbr\u003eRoHS and Proposition 65 compliant\u003cbr\u003eAssembled in USA\u003cbr\u003e 1 year warranty\u003cbr\u003e\u003ca data-mce-fragment=\"1\" title=\"Lew Electric PUFP-CT-GFI-PB Drawing (PDF)\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-GFI-PB.pdf?v=1641319705\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-GFI-PB.pdf?v=1641319705\"\u003eDrawing (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/OPERATING-INSTRUCTIONS-FOR-PUFP.pdf?8274546365573086000\" title=\"Lew Electric PUFP-CT-SS Operating Instructions (PDF)\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/OPERATING-INSTRUCTIONS-FOR-PUFP.pdf?8274546365573086000\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" title=\"Lew Electric PUFP-CT-PB Installation Instructions (PDF)\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_Electric_PUFP-CT-PB_Installation_Instructions.pdf?v=1642511588\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_Electric_PUFP-CT-PB_Installation_Instructions.pdf?v=1642511588\"\u003eInstallation Instructions (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_INSTALLATION_INSTRUCTIONS_KPPU.pdf?5481953841507266079\" title=\"Lew Electric PUFP-CT-SS Installation Instructions (PDF)\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_INSTALLATION_INSTRUCTIONS_KPPU.pdf?5481953841507266079\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/a\u003e\u003ca title=\"ETL Installation Certification PDF\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT-non-corded_ETL-Certification-sell-sheet-V05_1.pdf?v=1702569135\" target=\"_blank\"\u003eETL Installation Certification (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" title=\"ETL Installation Certification PDF\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-PB_Pop_Up_Outlet_ETL_Certification.pdf?v=1642650944\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-PB_Pop_Up_Outlet_ETL_Certification.pdf?v=1642650944\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003ca title=\"Lew Electric PUFP-CT-PB Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP_Brochure_2023.pdf?v=1702567997\" target=\"_blank\"\u003eBrochure (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" title=\"Lew Electric PUFP-CT-PB Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_Spring_2022_New_Design_Features.pdf?v=1643068238\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_Spring_2022_New_Design_Features.pdf?v=1643068238\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/2023-12_PUFP-CT_2023_Spill_Proof_v01.PDF?v=1702568103\" target=\"_blank\"\u003eUL 498 and NEC 2023 Explained (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-7\"\u003e\n\u003cbr\u003e \u003ciframe width=\"100%\" height=\"375\" src=\"https:\/\/www.youtube.com\/embed\/S9x2dHGd_dY\" frameborder=\"0\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eColor:  Dark bronze metal top\u003cbr\u003e Outlet:  20 Amp GFCI\u003cbr\u003e Tamper resistant (TR) plugs\u003cbr\u003eWeather resistant (WR) outlet\u003cbr\u003e Meets 2017 to 2023 NEC code 406.5E\u003cbr\u003e ETL listed for USA installations, # 4004534\u003cbr\u003ecETL listed for Canada installation, # 4004534\u003cbr\u003eCSA approved for Canada, #C22.2\u003cbr\u003eConforms to UL 498 and 943\u003cbr\u003eUL listed receptacle, # E60120\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003ePassed half-gallon spill test\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ePassed endurance, mechanical, dielectric, temperature tests\u003c\/span\u003e\u003cbr\u003e Gasket under bezel to keep water out\u003cbr\u003e Bezel size:  4 7\/8” x 4 11\/16”\u003cbr\u003e Cutout size:  4 1\/8” x 4 1\/8”\u003cbr\u003e Depth under 3cm counter:  1.97”\u003cbr\u003e Back box dimensions:  4.1062” x 4”\u003cbr\u003e Works in counter thickness up to 1.9”\u003cbr\u003e Hardwired power, no corded plug\u003cbr\u003e Includes back box with threaded lock nut, screws\u003cbr\u003e Installation should be done by a licensed electrician\u003cbr\u003e Consult with electrician\/inspector before ordering \u003cbr\u003eDesigned for indoor installations only\u003cbr\u003e RoHS and Proposition 65 compliant\u003cbr\u003eAssembled in USA\u003cbr\u003e1 year warranty\u003cbr\u003e\u003ca data-mce-fragment=\"1\" title=\"Lew Electric PUFP-CT-GFI-PB Drawing (PDF)\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-GFI-PB.pdf?v=1641319705\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-GFI-PB.pdf?v=1641319705\"\u003eDrawing (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/OPERATING-INSTRUCTIONS-FOR-PUFP.pdf?8274546365573086000\" title=\"Lew Electric PUFP-CT-SS Operating Instructions (PDF)\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/OPERATING-INSTRUCTIONS-FOR-PUFP.pdf?8274546365573086000\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" title=\"Lew Electric PUFP-CT-PB Installation Instructions (PDF)\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_Electric_PUFP-CT-PB_Installation_Instructions.pdf?v=1642511588\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_Electric_PUFP-CT-PB_Installation_Instructions.pdf?v=1642511588\"\u003eInstallation Instructions (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_INSTALLATION_INSTRUCTIONS_KPPU.pdf?5481953841507266079\" title=\"Lew Electric PUFP-CT-SS Installation Instructions (PDF)\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_INSTALLATION_INSTRUCTIONS_KPPU.pdf?5481953841507266079\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" title=\"ETL Installation Certification PDF\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT-non-corded_ETL-Certification-sell-sheet-V05_1.pdf?v=1702569135\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT-non-corded_ETL-Certification-sell-sheet-V05_1.pdf?v=1702569135\"\u003eETL Installation Certification (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" title=\"ETL Installation Certification PDF\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-PB_Pop_Up_Outlet_ETL_Certification.pdf?v=1642650944\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-PB_Pop_Up_Outlet_ETL_Certification.pdf?v=1642650944\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003ca data-mce-fragment=\"1\" title=\"Lew Electric PUFP-CT-PB Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP_Brochure_2023.pdf?v=1702567997\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP_Brochure_2023.pdf?v=1702567997\"\u003eBrochure (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" title=\"Lew Electric PUFP-CT-PB Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_Spring_2022_New_Design_Features.pdf?v=1643068238\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_Spring_2022_New_Design_Features.pdf?v=1643068238\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/2023-12_PUFP-CT_2023_Spill_Proof_v01.PDF?v=1702568103\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/2023-12_PUFP-CT_2023_Spill_Proof_v01.PDF?v=1702568103\"\u003eUL 498 and NEC 2023 Explained (PDF)\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eDownloads (PDF's)\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-GFI-PB.pdf?v=1641319705\" title=\"Lew Electric PUFP-CT-GFI-PB Drawing (PDF)\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-GFI-PB.pdf?v=1641319705\" target=\"_blank\"\u003eDrawing (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" title=\"Lew Electric PUFP-CT-SS Operating Instructions (PDF)\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/OPERATING-INSTRUCTIONS-FOR-PUFP.pdf?8274546365573086000\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/OPERATING-INSTRUCTIONS-FOR-PUFP.pdf?8274546365573086000\" target=\"_blank\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_Electric_PUFP-CT-PB_Installation_Instructions.pdf?v=1642511588\" title=\"Lew Electric PUFP-CT-PB Installation Instructions (PDF)\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_Electric_PUFP-CT-PB_Installation_Instructions.pdf?v=1642511588\" target=\"_blank\"\u003eInstallation Instructions (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" title=\"Lew Electric PUFP-CT-SS Installation Instructions (PDF)\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_INSTALLATION_INSTRUCTIONS_KPPU.pdf?5481953841507266079\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_INSTALLATION_INSTRUCTIONS_KPPU.pdf?5481953841507266079\" target=\"_blank\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT-non-corded_ETL-Certification-sell-sheet-V05_1.pdf?v=1702569135\" title=\"ETL Installation Certification PDF\" target=\"_blank\"\u003eETL Installation Certification (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-PB_Pop_Up_Outlet_ETL_Certification.pdf?v=1642650944\" title=\"ETL Installation Certification PDF\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-PB_Pop_Up_Outlet_ETL_Certification.pdf?v=1642650944\" target=\"_blank\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP_Brochure_2023.pdf?v=1702567997\" title=\"Lew Electric PUFP-CT-PB Brochure\" target=\"_blank\"\u003eBrochure (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_Spring_2022_New_Design_Features.pdf?v=1643068238\" title=\"Lew Electric PUFP-CT-PB Brochure\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_Spring_2022_New_Design_Features.pdf?v=1643068238\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/2023-12_PUFP-CT_2023_Spill_Proof_v01.PDF?v=1702568103\" target=\"_blank\"\u003eUL 498 and NEC 2023 Explained (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_INSTALLATION_INSTRUCTIONS_KPPU.pdf?5481953841507266079\" title=\"Lew Electric PUFP-CT-SS Installation Instructions (PDF)\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003e\u003cbr\u003eShipping \u0026amp; Returns\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Policy\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e \u003c\/strong\u003eThis item qualifies for free ground shipping to anywhere in the USA and Canada. In-stock orders are shipped the same business day Monday-Friday from Boise, ID if ordered by 6pm EST.\u003cbr\u003e \u003cstrong\u003eReturn Policy\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e \u003c\/strong\u003eIf you are not completely satisfied with your purchase you may return this item for a full refund of the merchandise total, the return request must be made within 45 days from order date. Please note that you are responsible for all return shipping charges unless the item is defective or damaged. Return credits are issued within 5 business days to your original method of payment once the item is received and inspected.\u003cbr\u003e \u003cstrong\u003eReturn Eligibility\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e \u003c\/strong\u003eItems must be in new condition and in the original packaging to qualify for a full refund (please do not modify the product in any way). If these conditions are not met, then the return could be subject to a restocking fee, or the product sent back to sender.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e","published_at":"2022-01-25T16:40:14-07:00","created_at":"2022-01-25T16:40:14-07:00","vendor":"Lew Electric","type":"Kitchen Pop Up Outlet","tags":["2017","2020","2023","amperage_20-amps","availability_in-stock","bezel-design_square","box_plastic","brand_lew-electric","charging-usb_no","depth-under-counter_2","diameter_4-88x4-69","finish_bronze","gfci-protected_yes","in-stock-inventory","mounting-style_surface","plugs_2","power-connection_hardwired","tamper-resistant_yes","thick_-12","water-64","wireless-charging_no"],"price":22400,"price_min":22400,"price_max":22400,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39434840473696,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"PUFP-CT-DB-PB","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Kitchen Counter Pop Up Receptacle, 20A GFCI, Plastic Back Box, Dark Bronze","public_title":null,"options":["Default Title"],"price":22400,"weight":964,"compare_at_price":null,"inventory_quantity":9,"inventory_management":"shopify","inventory_policy":"continue","barcode":"784149408339","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/www.kitchenpowerpopups.com\/cdn\/shop\/products\/PUFP-CT-DB_lidonly_-min.jpg?v=1643158292","\/\/www.kitchenpowerpopups.com\/cdn\/shop\/products\/PUFP-CT-DB-PB_-min.jpg?v=1643158302","\/\/www.kitchenpowerpopups.com\/cdn\/shop\/products\/PUFP-CT-DB-PBclosed_-min_c2b53cbd-04b3-4a05-b11e-570d8913c8e9.jpg?v=1643158291","\/\/www.kitchenpowerpopups.com\/cdn\/shop\/products\/pufppbunder_13d32d96-bec1-47cb-8c64-a4ba0233024b.jpg?v=1643154210","\/\/www.kitchenpowerpopups.com\/cdn\/shop\/products\/pufp-ct-pbthumb_6d6665e3-307e-4371-88e5-01b27c9f64b3.png?v=1643158290"],"featured_image":"\/\/www.kitchenpowerpopups.com\/cdn\/shop\/products\/PUFP-CT-DB_lidonly_-min.jpg?v=1643158292","options":["Title"],"media":[{"alt":"Kitchen Countertop Pop Up Electrical Outlet, 20A GFCI, Dark Bronze","id":20728367415392,"position":1,"preview_image":{"aspect_ratio":1.0,"height":2839,"width":2839,"src":"\/\/www.kitchenpowerpopups.com\/cdn\/shop\/products\/PUFP-CT-DB_lidonly_-min.jpg?v=1643158292"},"aspect_ratio":1.0,"height":2839,"media_type":"image","src":"\/\/www.kitchenpowerpopups.com\/cdn\/shop\/products\/PUFP-CT-DB_lidonly_-min.jpg?v=1643158292","width":2839},{"alt":"Kitchen Countertop Pop Up Electrical Outlet, 20A GFCI, Dark Bronze, Showing Entire Unit","id":20728367448160,"position":2,"preview_image":{"aspect_ratio":1.0,"height":3075,"width":3075,"src":"\/\/www.kitchenpowerpopups.com\/cdn\/shop\/products\/PUFP-CT-DB-PB_-min.jpg?v=1643158302"},"aspect_ratio":1.0,"height":3075,"media_type":"image","src":"\/\/www.kitchenpowerpopups.com\/cdn\/shop\/products\/PUFP-CT-DB-PB_-min.jpg?v=1643158302","width":3075},{"alt":"Kitchen Countertop Pop Up Electrical Outlet, 20A GFCI, Dark Bronze, Showing Top Closed","id":20728367480928,"position":3,"preview_image":{"aspect_ratio":1.0,"height":2569,"width":2569,"src":"\/\/www.kitchenpowerpopups.com\/cdn\/shop\/products\/PUFP-CT-DB-PBclosed_-min_c2b53cbd-04b3-4a05-b11e-570d8913c8e9.jpg?v=1643158291"},"aspect_ratio":1.0,"height":2569,"media_type":"image","src":"\/\/www.kitchenpowerpopups.com\/cdn\/shop\/products\/PUFP-CT-DB-PBclosed_-min_c2b53cbd-04b3-4a05-b11e-570d8913c8e9.jpg?v=1643158291","width":2569},{"alt":"Showing how it only takes up 1.97\" of space under a 3cm counter","id":20728365908064,"position":4,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"\/\/www.kitchenpowerpopups.com\/cdn\/shop\/products\/pufppbunder_13d32d96-bec1-47cb-8c64-a4ba0233024b.jpg?v=1643154210"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"\/\/www.kitchenpowerpopups.com\/cdn\/shop\/products\/pufppbunder_13d32d96-bec1-47cb-8c64-a4ba0233024b.jpg?v=1643154210","width":500},{"alt":"\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/S9x2dHGd_dY\" width=\"897\" height=\"360\" frameborder=\"0\" allowfullscreen\u003e\u003c\/iframe\u003e","id":20728365940832,"position":5,"preview_image":{"aspect_ratio":1.0,"height":617,"width":617,"src":"\/\/www.kitchenpowerpopups.com\/cdn\/shop\/products\/pufp-ct-pbthumb_6d6665e3-307e-4371-88e5-01b27c9f64b3.png?v=1643158290"},"aspect_ratio":1.0,"height":617,"media_type":"image","src":"\/\/www.kitchenpowerpopups.com\/cdn\/shop\/products\/pufp-ct-pbthumb_6d6665e3-307e-4371-88e5-01b27c9f64b3.png?v=1643158290","width":617}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg style=\"margin-top: 10px; margin-right: 6px; margin-bottom: 6px; float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT-SS-AC-PBGIF_480x480.gif?v=1702520985\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan style=\"color: #59115a;\"\u003e\u003cstrong\u003eLew Electric PUFP-CT-DB-PB Pop Up Countertop GFCI Outlet in Dark Bronze\u003c\/strong\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003eThe pop up power outlet box is designed to be hidden in kitchen countertops, or any worktop surface that needs protection from liquids while meeting UL 498 code. When in the closed position, the outlet sits recessed in the counter, creating a sleek and attractive appearance. When access to power is needed, simply press the oval button and the outlet flips up for use. The durable metal top is a dark bronze color that is perfect for matching dark countertops or oil rubbed bronze fixtures. \u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan style=\"color: #59115a;\"\u003e\u003cstrong\u003eMeets NEC Electrical Code 2023 406.5E for Installation in Countertops\u003c\/strong\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe pop up meets 2017, 2020, and 2023 NEC 406.5E for kitchen countertop installations in the USA and Canada. The single duplex GFCI outlet has tamper-proof plugs and is UL 498 listed. The pop up has passed the UL 498 half gallon spill test, as well as endurance, mechanical load, dielectric voltage, and temperature tests. There is also a gasket under the bezel to keep liquids from entering the sides between the countertop and the base of the pop up.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #59115a;\"\u003e\u003cem\u003e\u003cstrong\u003eEasy to Thread on Lock Nut Installation with a Shallow Depth\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe pop up only needs 1.97” of space under a 3cm countertop, and requires a 4 1\/8” x 4 1\/8” hole to be cut for installation. A plastic back box features a lock nut that makes it extremely easy to install, simply thread the lock nut on the box to secure to the underside of the counter. The outlet does not have a power cord; simply hardwire power into the outlet by running it through the knockouts in the rear of the back box.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #59115a;\"\u003e\u003cem\u003e\u003cstrong\u003eTamper Proof GFCI 20A Outlet for Safety\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe outlet is 20 Amp rated allowing the most power hungry small appliances to be plugged in. The outlet has integrated GFCI protection providing safety right at the source, if the outlet recognizes an unsafe interruption in the current, it will automatically shut off power to the outlet. The plugs are tamper resistant (TR) meeting code, and offer the peace of mind knowing that children can't put small objects into the sockets and electrocute themselves. The 20A outlet is backwards compatible with 15A plugs, meaning that both 15A plugs and 20A plugs, can be plugged into the outlet. The outlet meets the ANSI\/UL 943 standard for safety for ground fault circuit interrupters. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e***NEC 2023 Code states that outlets can no longer be placed on the sides of islands anymore, use an approved pop up outlet in your countertop that meets UL 498 code***\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #59115a;\"\u003e\u003cem\u003e\u003cstrong\u003eIn-Counter Outlet Where it is Needed Most\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA centrally located inset countertop tilt up outlet adds convenience to provide power and charging where needed most. Eliminate the need to plug into the side of an island, and unsafely drape cords over the edge of the counter. Never again run cords over the counter hoping it reaches the middle of your island. If you are wanting to meet 2023 code, then you can place the outlet in the top of the countertop.  Pop up outlets provide a functional, safe, and beautiful look in your countertop.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan style=\"color: #59115a;\"\u003e\u003cstrong\u003ePlug in Power for Numerous Applications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe Lew Electric PUFP-CT-DB-PB meets electrical code for kitchen countertop installations, but can also be used in any other potentially wet locations that require recessed power such as pantries, closets, garage work benches, bars, and varied uses at airports, hotels and restaurants. Use the pop up to power small appliances such as coffee makers, blenders, toaster ovens, warming trays, and other items. It can also be used for charging mobile devices such as tablets and phones with an appropriate adapter. The pop up can be installed in granite, quartz, marble, wood, laminate, concrete, or any surface up to 1.9\" where the required 4 1\/8” x 4 1\/8” hole can be cut.\u003c\/p\u003e\n\u003cp\u003eWatch a customer demonstration video \u003ca href=\"https:\/\/www.youtube.com\/shorts\/uBwhdfs27Cw\" target=\"_blank\"\u003eCLICK HERE.\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan color=\"#59115a\" style=\"color: #59115a;\"\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-lg-5 col-lg-5-offset-2\"\u003e\n\u003cp\u003eColor:  Dark bronze metal top\u003cbr\u003e Outlet:  20 Amp GFCI\u003cbr\u003e Tamper resistant (TR) plugs\u003cbr\u003eWeather resistant (WR) outlet\u003cbr\u003e Meets 2017 to 2023 NEC code 406.5E\u003cbr\u003e ETL listed for USA installations, # 4004534\u003cbr\u003ecETL listed for Canada installation, # 4004534\u003cbr\u003eCSA approved for Canada, #C22.2\u003cbr\u003eConforms to UL 498 and 943\u003cbr\u003eUL listed receptacle, # E60120\u003cbr\u003ePassed half-gallon spill test\u003cbr\u003ePassed endurance, mechanical, dielectric, temperature tests\u003cbr\u003e Gasket under bezel to keep water out\u003cbr\u003e Bezel size:  4 7\/8” x 4 11\/16”\u003cbr\u003e Cutout size:  4 1\/8” x 4 1\/8”\u003cbr\u003e Depth under 3cm counter:  1.97”\u003cbr\u003e Back box dimensions:  4.1062” x 4”\u003cbr\u003e Works in counter thickness up to 1.9”\u003cbr\u003e Hardwired power, no corded plug\u003cbr\u003e Includes back box with threaded lock nut, screws\u003cbr\u003e Installation should be done by a licensed electrician\u003cbr\u003e Consult with electrician\/inspector before ordering \u003cbr\u003eDesigned for indoor installations only\u003cbr\u003eRoHS and Proposition 65 compliant\u003cbr\u003eAssembled in USA\u003cbr\u003e 1 year warranty\u003cbr\u003e\u003ca data-mce-fragment=\"1\" title=\"Lew Electric PUFP-CT-GFI-PB Drawing (PDF)\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-GFI-PB.pdf?v=1641319705\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-GFI-PB.pdf?v=1641319705\"\u003eDrawing (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/OPERATING-INSTRUCTIONS-FOR-PUFP.pdf?8274546365573086000\" title=\"Lew Electric PUFP-CT-SS Operating Instructions (PDF)\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/OPERATING-INSTRUCTIONS-FOR-PUFP.pdf?8274546365573086000\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" title=\"Lew Electric PUFP-CT-PB Installation Instructions (PDF)\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_Electric_PUFP-CT-PB_Installation_Instructions.pdf?v=1642511588\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_Electric_PUFP-CT-PB_Installation_Instructions.pdf?v=1642511588\"\u003eInstallation Instructions (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_INSTALLATION_INSTRUCTIONS_KPPU.pdf?5481953841507266079\" title=\"Lew Electric PUFP-CT-SS Installation Instructions (PDF)\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_INSTALLATION_INSTRUCTIONS_KPPU.pdf?5481953841507266079\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/a\u003e\u003ca title=\"ETL Installation Certification PDF\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT-non-corded_ETL-Certification-sell-sheet-V05_1.pdf?v=1702569135\" target=\"_blank\"\u003eETL Installation Certification (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" title=\"ETL Installation Certification PDF\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-PB_Pop_Up_Outlet_ETL_Certification.pdf?v=1642650944\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-PB_Pop_Up_Outlet_ETL_Certification.pdf?v=1642650944\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003ca title=\"Lew Electric PUFP-CT-PB Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP_Brochure_2023.pdf?v=1702567997\" target=\"_blank\"\u003eBrochure (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" title=\"Lew Electric PUFP-CT-PB Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_Spring_2022_New_Design_Features.pdf?v=1643068238\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_Spring_2022_New_Design_Features.pdf?v=1643068238\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/2023-12_PUFP-CT_2023_Spill_Proof_v01.PDF?v=1702568103\" target=\"_blank\"\u003eUL 498 and NEC 2023 Explained (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-7\"\u003e\n\u003cbr\u003e \u003ciframe width=\"100%\" height=\"375\" src=\"https:\/\/www.youtube.com\/embed\/S9x2dHGd_dY\" frameborder=\"0\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eColor:  Dark bronze metal top\u003cbr\u003e Outlet:  20 Amp GFCI\u003cbr\u003e Tamper resistant (TR) plugs\u003cbr\u003eWeather resistant (WR) outlet\u003cbr\u003e Meets 2017 to 2023 NEC code 406.5E\u003cbr\u003e ETL listed for USA installations, # 4004534\u003cbr\u003ecETL listed for Canada installation, # 4004534\u003cbr\u003eCSA approved for Canada, #C22.2\u003cbr\u003eConforms to UL 498 and 943\u003cbr\u003eUL listed receptacle, # E60120\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003ePassed half-gallon spill test\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ePassed endurance, mechanical, dielectric, temperature tests\u003c\/span\u003e\u003cbr\u003e Gasket under bezel to keep water out\u003cbr\u003e Bezel size:  4 7\/8” x 4 11\/16”\u003cbr\u003e Cutout size:  4 1\/8” x 4 1\/8”\u003cbr\u003e Depth under 3cm counter:  1.97”\u003cbr\u003e Back box dimensions:  4.1062” x 4”\u003cbr\u003e Works in counter thickness up to 1.9”\u003cbr\u003e Hardwired power, no corded plug\u003cbr\u003e Includes back box with threaded lock nut, screws\u003cbr\u003e Installation should be done by a licensed electrician\u003cbr\u003e Consult with electrician\/inspector before ordering \u003cbr\u003eDesigned for indoor installations only\u003cbr\u003e RoHS and Proposition 65 compliant\u003cbr\u003eAssembled in USA\u003cbr\u003e1 year warranty\u003cbr\u003e\u003ca data-mce-fragment=\"1\" title=\"Lew Electric PUFP-CT-GFI-PB Drawing (PDF)\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-GFI-PB.pdf?v=1641319705\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-GFI-PB.pdf?v=1641319705\"\u003eDrawing (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/OPERATING-INSTRUCTIONS-FOR-PUFP.pdf?8274546365573086000\" title=\"Lew Electric PUFP-CT-SS Operating Instructions (PDF)\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/OPERATING-INSTRUCTIONS-FOR-PUFP.pdf?8274546365573086000\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" title=\"Lew Electric PUFP-CT-PB Installation Instructions (PDF)\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_Electric_PUFP-CT-PB_Installation_Instructions.pdf?v=1642511588\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_Electric_PUFP-CT-PB_Installation_Instructions.pdf?v=1642511588\"\u003eInstallation Instructions (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_INSTALLATION_INSTRUCTIONS_KPPU.pdf?5481953841507266079\" title=\"Lew Electric PUFP-CT-SS Installation Instructions (PDF)\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_INSTALLATION_INSTRUCTIONS_KPPU.pdf?5481953841507266079\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" title=\"ETL Installation Certification PDF\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT-non-corded_ETL-Certification-sell-sheet-V05_1.pdf?v=1702569135\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT-non-corded_ETL-Certification-sell-sheet-V05_1.pdf?v=1702569135\"\u003eETL Installation Certification (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" title=\"ETL Installation Certification PDF\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-PB_Pop_Up_Outlet_ETL_Certification.pdf?v=1642650944\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-PB_Pop_Up_Outlet_ETL_Certification.pdf?v=1642650944\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003ca data-mce-fragment=\"1\" title=\"Lew Electric PUFP-CT-PB Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP_Brochure_2023.pdf?v=1702567997\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP_Brochure_2023.pdf?v=1702567997\"\u003eBrochure (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" title=\"Lew Electric PUFP-CT-PB Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_Spring_2022_New_Design_Features.pdf?v=1643068238\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_Spring_2022_New_Design_Features.pdf?v=1643068238\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/2023-12_PUFP-CT_2023_Spill_Proof_v01.PDF?v=1702568103\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/2023-12_PUFP-CT_2023_Spill_Proof_v01.PDF?v=1702568103\"\u003eUL 498 and NEC 2023 Explained (PDF)\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eDownloads (PDF's)\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-GFI-PB.pdf?v=1641319705\" title=\"Lew Electric PUFP-CT-GFI-PB Drawing (PDF)\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-GFI-PB.pdf?v=1641319705\" target=\"_blank\"\u003eDrawing (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" title=\"Lew Electric PUFP-CT-SS Operating Instructions (PDF)\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/OPERATING-INSTRUCTIONS-FOR-PUFP.pdf?8274546365573086000\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/OPERATING-INSTRUCTIONS-FOR-PUFP.pdf?8274546365573086000\" target=\"_blank\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_Electric_PUFP-CT-PB_Installation_Instructions.pdf?v=1642511588\" title=\"Lew Electric PUFP-CT-PB Installation Instructions (PDF)\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_Electric_PUFP-CT-PB_Installation_Instructions.pdf?v=1642511588\" target=\"_blank\"\u003eInstallation Instructions (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" title=\"Lew Electric PUFP-CT-SS Installation Instructions (PDF)\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_INSTALLATION_INSTRUCTIONS_KPPU.pdf?5481953841507266079\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_INSTALLATION_INSTRUCTIONS_KPPU.pdf?5481953841507266079\" target=\"_blank\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT-non-corded_ETL-Certification-sell-sheet-V05_1.pdf?v=1702569135\" title=\"ETL Installation Certification PDF\" target=\"_blank\"\u003eETL Installation Certification (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-PB_Pop_Up_Outlet_ETL_Certification.pdf?v=1642650944\" title=\"ETL Installation Certification PDF\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/Lew_PUFP-CT-PB_Pop_Up_Outlet_ETL_Certification.pdf?v=1642650944\" target=\"_blank\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP_Brochure_2023.pdf?v=1702567997\" title=\"Lew Electric PUFP-CT-PB Brochure\" target=\"_blank\"\u003eBrochure (PDF)\u003c\/a\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_Spring_2022_New_Design_Features.pdf?v=1643068238\" title=\"Lew Electric PUFP-CT-PB Brochure\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_Spring_2022_New_Design_Features.pdf?v=1643068238\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/2023-12_PUFP-CT_2023_Spill_Proof_v01.PDF?v=1702568103\" target=\"_blank\"\u003eUL 498 and NEC 2023 Explained (PDF)\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2052\/0581\/files\/PUFP-CT_INSTALLATION_INSTRUCTIONS_KPPU.pdf?5481953841507266079\" title=\"Lew Electric PUFP-CT-SS Installation Instructions (PDF)\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003e\u003cbr\u003eShipping \u0026amp; Returns\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Policy\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e \u003c\/strong\u003eThis item qualifies for free ground shipping to anywhere in the USA and Canada. In-stock orders are shipped the same business day Monday-Friday from Boise, ID if ordered by 6pm EST.\u003cbr\u003e \u003cstrong\u003eReturn Policy\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e \u003c\/strong\u003eIf you are not completely satisfied with your purchase you may return this item for a full refund of the merchandise total, the return request must be made within 45 days from order date. Please note that you are responsible for all return shipping charges unless the item is defective or damaged. Return credits are issued within 5 business days to your original method of payment once the item is received and inspected.\u003cbr\u003e \u003cstrong\u003eReturn Eligibility\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e \u003c\/strong\u003eItems must be in new condition and in the original packaging to qualify for a full refund (please do not modify the product in any way). If these conditions are not met, then the return could be subject to a restocking fee, or the product sent back to sender.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e"}

Kitchen Counter Pop Up Receptacle, 20A GFCI, Plastic Back Box, Dark Bronze

290 reviews   |   Q&A

$224.00

Free 4-Day Shipping!

Part #: PUFP-CT-DB-PB
Vendor: Lew Electric
In Stock!
Ships same business day from Boise, ID if ordered by 6pm EST
Ship To:
Check Arrival Date and Cost
Estimated Arrival
Estimated Cost
Maximum quantity available reached.

Lew Electric PUFP-CT-DB-PB Pop Up Countertop GFCI Outlet in Dark Bronze

The pop up power outlet box is designed to be hidden in kitchen countertops, or any worktop surface that needs protection from liquids while meeting UL 498 code. When in the closed position, the outlet sits recessed in the counter, creating a sleek and attractive appearance. When access to power is needed, simply press the oval button and the outlet flips up for use. The durable metal top is a dark bronze color that is perfect for matching dark countertops or oil rubbed bronze fixtures. 

Meets NEC Electrical Code 2023 406.5E for Installation in Countertops

The pop up meets 2017, 2020, and 2023 NEC 406.5E for kitchen countertop installations in the USA and Canada. The single duplex GFCI outlet has tamper-proof plugs and is UL 498 listed. The pop up has passed the UL 498 half gallon spill test, as well as endurance, mechanical load, dielectric voltage, and temperature tests. There is also a gasket under the bezel to keep liquids from entering the sides between the countertop and the base of the pop up.

Easy to Thread on Lock Nut Installation with a Shallow Depth

The pop up only needs 1.97” of space under a 3cm countertop, and requires a 4 1/8” x 4 1/8” hole to be cut for installation. A plastic back box features a lock nut that makes it extremely easy to install, simply thread the lock nut on the box to secure to the underside of the counter. The outlet does not have a power cord; simply hardwire power into the outlet by running it through the knockouts in the rear of the back box.

Tamper Proof GFCI 20A Outlet for Safety

The outlet is 20 Amp rated allowing the most power hungry small appliances to be plugged in. The outlet has integrated GFCI protection providing safety right at the source, if the outlet recognizes an unsafe interruption in the current, it will automatically shut off power to the outlet. The plugs are tamper resistant (TR) meeting code, and offer the peace of mind knowing that children can't put small objects into the sockets and electrocute themselves. The 20A outlet is backwards compatible with 15A plugs, meaning that both 15A plugs and 20A plugs, can be plugged into the outlet. The outlet meets the ANSI/UL 943 standard for safety for ground fault circuit interrupters. 

***NEC 2023 Code states that outlets can no longer be placed on the sides of islands anymore, use an approved pop up outlet in your countertop that meets UL 498 code***

In-Counter Outlet Where it is Needed Most

A centrally located inset countertop tilt up outlet adds convenience to provide power and charging where needed most. Eliminate the need to plug into the side of an island, and unsafely drape cords over the edge of the counter. Never again run cords over the counter hoping it reaches the middle of your island. If you are wanting to meet 2023 code, then you can place the outlet in the top of the countertop.  Pop up outlets provide a functional, safe, and beautiful look in your countertop.

Plug in Power for Numerous Applications

The Lew Electric PUFP-CT-DB-PB meets electrical code for kitchen countertop installations, but can also be used in any other potentially wet locations that require recessed power such as pantries, closets, garage work benches, bars, and varied uses at airports, hotels and restaurants. Use the pop up to power small appliances such as coffee makers, blenders, toaster ovens, warming trays, and other items. It can also be used for charging mobile devices such as tablets and phones with an appropriate adapter. The pop up can be installed in granite, quartz, marble, wood, laminate, concrete, or any surface up to 1.9" where the required 4 1/8” x 4 1/8” hole can be cut.

Watch a customer demonstration video CLICK HERE.

Specifications:

Color:  Dark bronze metal top
Outlet:  20 Amp GFCI
Tamper resistant (TR) plugs
Weather resistant (WR) outlet
Meets 2017 to 2023 NEC code 406.5E
ETL listed for USA installations, # 4004534
cETL listed for Canada installation, # 4004534
CSA approved for Canada, #C22.2
Conforms to UL 498 and 943
UL listed receptacle, # E60120
Passed half-gallon spill test
Passed endurance, mechanical, dielectric, temperature tests
Gasket under bezel to keep water out
Bezel size:  4 7/8” x 4 11/16”
Cutout size:  4 1/8” x 4 1/8”
Depth under 3cm counter:  1.97”
Back box dimensions:  4.1062” x 4”
Works in counter thickness up to 1.9”
Hardwired power, no corded plug
Includes back box with threaded lock nut, screws
Installation should be done by a licensed electrician
Consult with electrician/inspector before ordering
Designed for indoor installations only
RoHS and Proposition 65 compliant
Assembled in USA
1 year warranty
Drawing (PDF)
Installation Instructions (PDF)
ETL Installation Certification (PDF)
Brochure (PDF)
UL 498 and NEC 2023 Explained (PDF)


Color:  Dark bronze metal top
Outlet:  20 Amp GFCI
Tamper resistant (TR) plugs
Weather resistant (WR) outlet
Meets 2017 to 2023 NEC code 406.5E
ETL listed for USA installations, # 4004534
cETL listed for Canada installation, # 4004534
CSA approved for Canada, #C22.2
Conforms to UL 498 and 943
UL listed receptacle, # E60120
Passed half-gallon spill test
Passed endurance, mechanical, dielectric, temperature tests
Gasket under bezel to keep water out
Bezel size:  4 7/8” x 4 11/16”
Cutout size:  4 1/8” x 4 1/8”
Depth under 3cm counter:  1.97”
Back box dimensions:  4.1062” x 4”
Works in counter thickness up to 1.9”
Hardwired power, no corded plug
Includes back box with threaded lock nut, screws
Installation should be done by a licensed electrician
Consult with electrician/inspector before ordering
Designed for indoor installations only
RoHS and Proposition 65 compliant
Assembled in USA
1 year warranty
Drawing (PDF)
Installation Instructions (PDF)
ETL Installation Certification (PDF)
Brochure (PDF)
UL 498 and NEC 2023 Explained (PDF)

Shipping Policy
This item qualifies for free ground shipping to anywhere in the USA and Canada. In-stock orders are shipped the same business day Monday-Friday from Boise, ID if ordered by 6pm EST.
Return Policy
If you are not completely satisfied with your purchase you may return this item for a full refund of the merchandise total, the return request must be made within 45 days from order date. Please note that you are responsible for all return shipping charges unless the item is defective or damaged. Return credits are issued within 5 business days to your original method of payment once the item is received and inspected.
Return Eligibility
Items must be in new condition and in the original packaging to qualify for a full refund (please do not modify the product in any way). If these conditions are not met, then the return could be subject to a restocking fee, or the product sent back to sender.

 

 

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question